Preconfiguration "PmKoyo - Minimal set of the PmaComm object"

Communication driver configuration PmKoyo - Driver for communication with PLC devices by the Koyo Electronics company.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the context menu of the object or by pressing the Insert key after selecting the object).
 
This preconfiguration is included in the "/ Communication / PLC devices and meters / Koyo" group.
 
This preconfiguration can be created in the PmaFolder, PmaRoot or PmaPrototype object.

Preconfiguration for serial link.
The created preconfigured connection is functional usually immediately. Otherwise it is necessary to obtain the connection parameters specified by the device manufacturer and see also PmKoyo - Driver for communication with PLC devices by the Koyo Electronics company.
These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma object tree.
The maximum name length is 30 characters.
This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and first character must not be a number.
Default: "Comm"
Serial portSelection of the communication serial port.
The value can be change by the OpenPort method.
The value can be detected by method GetProtParam("SerPort").
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Serial port" configurator will be set to this value.
Not set - The object is not connected to any port after the application is launched and the serial port can be selected dynamically by the algorithm (by the PmaComm.OpenPort method).
COM1, COM2,..,COM66 - The specified serial port is opened after the application is launched. This port must be correctly configured and accessible in Windows OS (no one can use it).
For serial link each PmaComm object must have defined another communication port. For example, if one PmaComm object communicates through COM1, then next PmaComm object can communicate for example through COM2 (COM3, …) but it mustn't communicate through COM1.
Baud rateSelection of the baud rate (bps, bit per second).
This configurator sets the initial value of the BaudRate property.
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Baud rate" configurator will be set to this value.
110
300
600
1200
2400
4800
9600
14400
19200
38400
57600
115200
128000
256000
Create examples of testing data for DL 205/405/05/06Create examples of testing data for DL 205/405/05/06
Create examples of testing data for DL305Create examples of testing data for DL305