Preconfiguration "PmMelsecFXS - Minimal set of the PmaComm object"

Communication driver configuration PmMelsecFXS - Driver for communication with Mitsubishi PLC devices of the FX series.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the context menu of the object or by pressing the Insert key after selecting the object).
 
This preconfiguration is included in the "/ Communication / PLC devices and meters / Mitsubishi" group.
 
This preconfiguration can be created in the PmaFolder, PmaRoot or PmaPrototype object.

These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma object tree.
The maximum name length is 30 characters.
This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and first character must not be a number.
Default: "Comm"
Communication type
Network TCP/IP communication (default)
Serial communication
Network addressNetwork address of the remote device (e.g. of the PLC device), to which the communication will be connected.
The address can be entered as:
- IPv4 full address (e.g. "192.168.0.15")
- IPv4 address of this computer (i.e. "127.0.0.1")
- IPv4 computer name (e.g. "server11")
- IPv4 name of this computer (i.e. "localhost")
- IPv6 full address (e.g. "2a02:c38:8136:800a:37a:ab66:6fc9:accd")
- IPv6 address of this computer (i.e. "::1")

Macro expression can be used for input (it is evaluated after the application is launched).
After the preconfiguration is created, the "PmaComm > Setting the parameters of the Ethernet-client > Network address" configurator will be set to this value.
TCP/UDP remote port numberEthernet remote port number for communication.
Values defined in the Ethernet converter.
Serial portSelection of the communication serial port.
The value can be change by the OpenPort method.
The value can be detected by method GetProtParam("SerPort").
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Serial port" configurator will be set to this value.
Not set - The object is not connected to any port after the application is launched and the serial port can be selected dynamically by the algorithm (by the PmaComm.OpenPort method).
COM1, COM2,..,COM66 - The specified serial port is opened after the application is launched. This port must be correctly configured and accessible in Windows OS (no one can use it).
For serial link each PmaComm object must have defined another communication port. For example, if one PmaComm object communicates through COM1, then next PmaComm object can communicate for example through COM2 (COM3, …) but it mustn't communicate through COM1.
Protocol version
General (all FX-series) - General FX protocol (older protocol but still supported in the devices of the 2nd series)
Extended (FX2N) - Extended protocol supported in the devices of the 2nd series
Create examples of testing dataA set of exemplary data is created
Communication refresh rate [ms]The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value.

History:
Pm8.00.05: Created
PROMOTIC 9.0.31 SCADA system documentation MICROSYS, spol. s r.o.