Preconfiguration "PmSNMP - Papouch PAPAGO 2x measurings (Communication by the SNMP protocol) - Communication set with data and panel"
Communication driver configuration
PmSNMP - Driver for communication by the SNMP protocol.
See also
Communication with meters by the Papouch company (Czechia).
The valid
TCP-IP address must be set for the device according to the corresponding network environment. The configuration is described in the documentation supplied by the manufacturer.
This preconfiguration can be activated when creating a new object (e.g. by
"New object ..." in the context menu of the object or by pressing the
Insert key after selecting the object).
This preconfiguration is included in the
"/ Communication / Protocols and other communications / SNMP" group.
This preconfiguration can be created in the
PmaFolder,
PmaRoot or
PmaPrototype object.
- The preconfiguration is created including the panel (object of the
PmaPanel type) is functional also as
Web panel.
- The panel serves for communication testing and it is not essential for the communication functionality.
In the
PmaComm object named "
Comm" the communication parameters are set (
Network address, ...).
The
PmaCommGroup object named "
data" includes a "
Parameters" tab where
Special Parameters are defined (see
PmSNMP - Driver for communication by the SNMP protocol). On the "
Data" tab, the items are imported by data extension of items defined in the
PmaData object (see
ExtComm). Each
Data corresponds to the selected device type by its structure and name.
These configurators can be set before the preconfiguration is created:
The name of created object | Name of the object created in the Pma object tree.
The maximum name length is 30 characters.
This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and first character must not be a number.
Default: "CommPapago" |
Meter type | 2x measurings according to the device type
2TH - 2x temperature and humidity meter
2PT - 2x thermometer for Pt100/1000
2TC - 2x thermometer for K-type thermocouple |
|
Network address | Network address of the remote device (e.g. of the PLC device), to which the communication will be connected.
The address can be entered as:
- IPv4 full address (e.g. "192.168.0.15")
- IPv4 address of this computer (i.e. "127.0.0.1")
- IPv4 computer name (e.g. "server11")
- IPv4 name of this computer (i.e. "localhost")
- IPv6 full address (e.g. "2a02:c38:8136:800a:37a:ab66:6fc9:accd")
- IPv6 address of this computer (i.e. "::1")
Macro expression can be used for input (it is evaluated after the application is launched).
After the preconfiguration is created, the "PmaComm > Setting the parameters of the Ethernet-client > Network address" configurator will be set to this value. |
Communication refresh rate [ms] | The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value. |
Panel title | Displayed in the panel header |
---|