Preconfiguration "PmOpcUaClient - Communication set with data and panel"

Communication driver configuration PmOpcUaClient - Driver for communication with OPC UA server.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the context menu of the object or by pressing the Insert key after selecting the object).
 
This preconfiguration is included in the "/ Communication / Protocols and other communications / OPC" group.
 
This preconfiguration can be created in the PmaFolder, PmaRoot or PmaPrototype object.

- The panel serves for communication testing and it is not essential for the communication functionality.


The created preconfigured connection is functional usually immediately. Otherwise it is necessary to obtain the connection parameters specified by the device manufacturer and see also PmOpcUaClient - Driver for communication with OPC UA server.
These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma object tree.
The maximum name length is 30 characters.
This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and first character must not be a number.
Default: "CommOpcUa"
Network addressNetwork address of the remote device (e.g. of the PLC device), to which the communication will be connected.
The address can be entered as:
- IPv4 full address (e.g. "192.168.0.15")
- IPv4 address of this computer (i.e. "127.0.0.1")
- IPv4 computer name (e.g. "server11")
- IPv4 name of this computer (i.e. "localhost")
- IPv6 full address (e.g. "2a02:c38:8136:800a:37a:ab66:6fc9:accd")
- IPv6 address of this computer (i.e. "::1")

Macro expression can be used for input (it is evaluated after the application is launched).
After the preconfiguration is created, the "PmaComm > Setting the parameters of the Ethernet-client > Network address" configurator will be set to this value.
TCP/UDP remote port numberEthernet remote port number for communication.
Communication refresh rate [ms]The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value.
Create examples of testing dataA set of exemplary data is created
Create panel for test dataCreates panel that monitors the statistics of communication values
Panel titleDisplayed in the panel header