Update cookies preferences
Promotic

Scale - tab of the PmgObject object

Description:
Settings for displaying the meter scale - location, color, font, number and length of ticks, scale description, etc.
This tab with its configurators is common for the following Pmg objects: PmgBarBox and PmgSliderBox.
Configurators:
Right / DownSee: "Left / Up".
Left / UpSelection of the scale location relative to the column.
Options "Right" and "Left" are considered for the case when the "Direction of growing" configurator is set to "Up" or "Down".
Options "Down" and "Up" are considered for the case when the "Direction of growing" configurator is set to "Right" or "Left".

Both options can be checked at once.
Scale colorSetting the color of scale main and minor ticks of the scale (at the panel meter also the color of the scale arc)
Color of the scale descriptionSetting the text color of the scale description
Font of the scale descriptionSetting the font of the scale description
Scale distanceDistance (in pixels) between the scale and the indicator of the measured variable (a bar or a finger)
Description distanceDistance between the scale and the scale description (in pixels)
Length of main ticksLength of main ticks of the scale (in pixels). Main ticks can be with or without the description. If minor ticks are defined as well, then the length of main ticks should be greater than the length of minor ticks.
Length of minor ticksLength of minor ticks of the scale (in pixels). Minor ticks are always without the description and they should be shorter than main ticks.
Number of main ticksThe number of main ticks specifies on how many parts is the scale divided. At the same time it is defined by this how many ticks can the description have. If the scale range is, for example, from 0 to 4, then there can be 5 main ticks (0,1,2,3,4) or 3 (0,2,4), but also 9 (0,0.5,1.0, ... 4.5,5.0).
Number of minor ticks in the main tickValue specifies the number of minor ticks between two main ticks is specified. Minor ticks have no description.
Which main tick has the descriptionHere the entered value specifies at which tick from the scale main ticks the value to the appropriate tick is shown. If this number is for example 3, then first main tick has the description, the second and the third main tick don't have the description, the forth main tick has the description, etc. This number must be an integer and greater or equal than one.
Number of decimal placesSetting the precision of the scale description

History:
Pm9.00.26: Fixed bug: Both scales were not displayed at the same time in the Web panel.
PROMOTIC 9.0.31 SCADA system documentation MICROSYS, spol. s r.o.

Send page remarkContact responsible person